Tuesday, August 12, 2008

Curtain Wall Doors and Levels

Curtain wall panel doors hosted in a curtain wall acquired the level from the level of the curtain wall. In this example the CW goes from level 1 to 4 and the doors are hosted at level 1, 2 and 3.

image

However, the schedule shows that all these CW panel doors are at level 1. This is the level the CW had as its "Base Constraint" when the doors were created.

image

Changing the base constraint of the CW to level 2 does not change the level value for the doors. There might be other better workarounds to show the correct level. The one that is shown here is long and winded. We used this one:

  1. Change the base constraint of the CW to the level you want to see in the schedule for a particular door. In this example, we made it Level 2 and then added a base offset of -10' , so that the CW looks the same after the level change.
    image
  2. Select the Door panel that is needed to be changed and swap this panel with the "CurtainWall : Curtain Wall 1" wall.  (This is a default CW type. It has no mullions / grids but only one panel)
    image
  3. Now TAB select the panel inside this "Curtain Wall : Curtain Wall 1" wall
    image
    and swap this with the door panel.
    image
    (You should NOT swap it with the whole "Curtain Wall : Curtain Wall 1" but the panel inside this CW.
  4. Now the schedule should show Level 2 for that particular door ("Curtain wall dbl glass"):
    image
  5. You might have to repeat relevant steps to change other doors. Changing the base constraint of the original CW back to Level 1 without and base offset does not affect the doors!

Monday, August 11, 2008

Multiply by count in schedules

When we try to multiply with the Count parameter in Revit, it spits out: "The field Count cannot be used in formulas.

image

For example, in a furniture schedule, after assigning $ values for various furniture, one cannot get an extended total for a set of particular items using the calculated value (= Count * Cost)

image

The work around is to create a calculated value named "ExtCost" (= Cost) which is equivalent to the cost parameter. The result looks like this.

image

Then go to the schedule properties > Formatting tab and select the ExtCost parameter and check Calculate Totals.

image

The result,

image

looks fine. But why do I have to do this?

Friday, August 8, 2008

View Reference and duplicate with detailing

This looks like a bug.

We tried to duplicate a view with detailing and got this error.

image

When we tried to duplicate the view or duplicate as dependent we didnt get any error.

Duplicating as a dependent and then trying to convert the duplicated view to an independent view gave the same error.

image

The view had some dependent views along with View References. Revit does not like these view references to be duplicated, which is fair. However, revit could have automatically removed the view references while duplicating the view.

The workaround is to select all the view references in the view; cut them to clipboard; duplicate the view with detailing; then paste aligned the cut view references in the same place.  May be there is a better way!

Monday, August 4, 2008

Archive a Revit Project

People asked me about archiving a Revit project. A Revit project gets a bit tricky with its linked DWG and RVT files, etc. Archiving in this sense, is not backing up, but creating a Revit project that is frozen in time, for eg., after a DD submittals.

  1. Everybody STC and relinquish everything.
  2. Make a PDF set of the whole project.
  3. Open the central file with the option ‘detach from central’.
     image
  4. Go to File menu > Manage Links and import the CAD links. 
    image
  5. Select any Revit link in the project and click on the "Bind" button in the option bar.
    image
  6. Go to File menu > Saveas to save here:
    “P:\year\project number\CADD\Revit\archive\yearmonthdate-project number-project name -_archive.rvt”

Thursday, July 31, 2008

Rotating Elevations

Elevation tags automatically align perpendicular to the wall. However, if we want to elevate a custom casework, etc., Revit does not rotate the tag and aligns it. In such a case, you could insert the elevation tag and then rotate it.

However, if you select the elevation and try to rotate it, Revit does NOT do anything.

image

To rotate it successfully, you need to select the whole elevation tag (in this case, the circle).

image